valvediagnostics.com beta
Valve Diagnostics : Analysis, Solutions
Valve Diagnostics HomeValve InstallationValve MaintenanceValve LeakageContact Velan Field Engineering Services
 
 

globe valve installation tips

 

  Always follow standard safety procedures when working on a valve.

Globe valves should usually be installed with the inlet below the valve seat. For severe throttling service, the valve may be installed so that the flow enters over the top of the seat and goes down through it. Note that in this arrangement, the packings will be constantly pressurized. If the valve is to be installed in near throttling service, verify with Velan Engineering. Globe valves per se are not suitable for throttling service.

The valve should be welded onto the line with the disc in the fully closed position. Leaving it even partially open can cause distortion and leaking. Allow time for the weld to cool before operating the valve the first time in the pipeline.

The preferred orientation of a globe valve is upright. The valve may be installed in other orientations, but any deviation from vertical is a compromise. Installation upside down is not recommended because it can cause dirt to accumulate in the bonnet.
 
     

© 2003 Velan Inc. All Rights Reserved.