diagnosis and suggested remedy
A butterfly valve may have jerky operation for the following reasons:

 

  1 The actuator/shaft adaptor is misaligned  
  Remove the actuator mounting and realign.  
       
  2 The packing is too tight  
  Loosen the packing torque until it is only hand tight. Tighten to the required level and then cycle the valve. Re-tighten, if required. CAUTION: Always follow safety instructions when operating on valve.  
       
  3 If the valve has a pneumatic actuator, the air supply may be inadequate.  
  Increase the air supply pressure to standard operating level.  
     