Any combination of the following may prevent the valve shaft from rotating:
The actuator is not working
Replace or repair the actuator as required. Please contact
Velan Field Engineering Services
for assistance.
The valve is packed with debris
Cycle the valve and then flush to remove debris. A full cleaning may be required if flushing the valve does not improve valve shaft rotation.
The shaft key has sheared
Contact
Velan Field Engineering Services
as a replacement shaft key is required.